Fire Shutter Doors

Compact Fire Rated Roller Shutter - Timber Stud Wall

From only £1,825.00 Ex VAT (£2,190.00 inc VAT)
(Based on 1000mm x 1000mm)

Get a Quote Today

Build your Quote & Buy Online

Key Product Features

Application

Commercial, Retail, Serveries

Product Rating

Fire Rated 1hr

Electric Operation

Single Phase - Tube Motor

Max Width

2950mm (Depending on Height)

Max Height

3020mm (Depending on Width)

Box and Guides - Standard Finish

Galvanised

Curtain - Standard Finish

Galvanised

Lead Times

15 working days

Compact Fire Shutter for Flexible Structures

Certified Fire Protection for Lightweight and Partition Wall Systems

The Compact Fire Shutter for Flexible Structures provides reliable, certified fire protection for non-load-bearing and lightweight wall constructions such as timber stud partitions, plasterboard walls, and modular systems. Designed to deliver up to 90 minutes of fire integrity, it offers the same dependable protection as traditional fire shutters — but in a lighter, space-saving form.

Fully tested to BS EN 1634-1:2014 + A1:2018 and classified to EN 13501-2:2023. It ensures full compliance for flexible wall applications where block or masonry structures are not suitable.

 

Key Features & Benefits

  • Independently Tested & Certified – Fire tested by Warringtonfire Testing & Certification Ltd, achieving up to E90 Integrity for installations into timber stud partitions.
  • Compliant with BS EN 16034:2014, EN 1634-1:2014 + A1:2018, and EN 13501-2:2023, ensuring full UKCA and CE compliance for flexible structures.
  • Lightweight Design – Engineered for stud and plasterboard walls without heavy reinforcement, ideal for offices, schools, retail units, and modular builds.
  • Compact Headbox – Small coil housing minimises visual impact, making it perfect for corridors, classrooms, or open-plan interiors.
  • Dependable Fire Integrity – Prevents fire and smoke spread through internal partitions and compartmentalised areas for up to 90 minutes.
  • Smooth Electric Operation – Driven by a single-phase tubular motor with integrated battery backup for reliable closure during alarm activation or power loss.
  • Optional Safety Interfaces – Can be supplied with audio-visual alarms, manual override, or staged descent systems to comply with BS EN 12604 safety guidance.

 

Designed for Flexible Wall Installations

This fire shutter is purpose-built for non-structural timber or plasterboard walls, with installation requirements designed to preserve tested performance:

  • Use minimum 100mm x 44mm C16 construction-grade timber for vertical and horizontal supports.
  • Double vertical studs (2 x 44mm) to form a 100mm fixing face for shutter guides.
  • Timber supports must extend full height of the shutter, securely tied into the surrounding structure at top and bottom.
  • Include horizontal noggins above the opening and at shutter box level for full perimeter support.
  • Wall surfaces must achieve 60-minute fire resistance, typically using two layers of 12.5mm fire-rated plasterboard.
  • These details ensure the shutter performs safely, maintains its E90 fire integrity, and resists distortion during fire exposure.

 

Technical Specification

ComponentSpecification
Fire RatingUp to E90 Integrity (90 minutes)
Supporting ConstructionTimber stud / plasterboard (Flexible Structure)
Curtain Design75mm curved interlocking galvanised steel, 0.7mm or 0.9mm thick
Guide Channels65mm x 32mm steel U-guides (tested specification)
Motor TypeSingle-phase tubular motor or gravity fail-safe motor
Control SystemFire alarm interface, UPS battery backup, manual override
FinishGalvanised as standard; powder coating optional (RAL/BS)
OperationFully automatic fire-closing mechanism triggered via BMS/fire alarm



 

Finish & Customisation Options

  • Supplied in galvanised steel as standard.
  • Optional powder coating to any RAL or BS colour for aesthetic integration.
  • Can be colour-matched to door frames, bulkheads, or corporate interiors.
  • Optional custom canopy and fascia plates available for architectural finishes.

 

Lead Time & Common Applications

  • Typical Lead Time: 3-4 weeks (subject to finish and configuration).
  • Best Suited For:
    • School corridors and classrooms
    • Office compartments and meeting rooms
    • Retail counters and concession areas
    • Canteens, kitchens, and food serveries
    • Lightweight or modular building systems

 

Compliance Summary

CertificationStandardIntegrity Rating
CE / UKCA MarkedBS EN 16034:2014
Fire TestingEN 1634-1:2014 + A1:2018E60 / E90
ClassificationEN 13501-2:2023
Supporting StructureTimber Stud Partition
Testing BodyWarringtonfire Testing & Certification Ltd

Information

Key Features – Compact Fire Shutter for Flexible Stud Wall Construction
 

Security Features

  • Durable Galvanised Steel Curtain – Manufactured from high-strength galvanised steel, providing reliable physical protection for internal applications such as kitchen serveries, reception counters, classrooms, and retail units.
  • Reinforced Stability – Fitted with precision-engineered galvanised steel “T” bottom rails and U-shaped guide channels (65mm, 75mm, or 100mm) for smooth and stable operation, even under high heat exposure.
  • Concealed Drive Mechanism – Operated by a single-phase tubular motor housed internally within the barrel for a clean aesthetic, quiet function, and reduced risk of tampering.

 

Safety Features

  • Independently Tested & Certified – Fully tested to BS EN 1634-1:2014 + A1:2018 and certified under BS EN 16034:2014, providing compliant fire protection for non-load-bearing and flexible wall systems.
  • Fire Integrity Rating – Up to 90 Minutes (E90) – Proven performance for timber stud partitions, meeting stringent UK and EU standards for compartmentation.
  • High-Performance Curtain Design – Constructed from 75mm curved interlocking steel slats, in 0.7mm or 0.9mm thickness depending on size and fire rating, ensuring stable descent and containment under fire conditions.
  • Fail-Safe Fire Operation – Integrated fire alarm interface triggers automatic closure on activation, supported by battery backup for operation during power loss and manual override for emergency use.
  • Enhanced Control Options – Compatible with audio-visual warning panels, emergency release switches, and staged or delayed descent systems for added safety and compliance with BS EN 12604:2017 + A1:2020.

 

Fire Safety & Construction Requirements

  • Certified to BS EN 16034:2014, tested to EN 1634-1:2014 + A1:2018, and classified under EN 13501-2:2023 by Warringtonfire Testing & Certification Ltd.
  • Specifically Tested for Timber Stud Walls – Installed and tested on C16-grade timber partitions, confirming full compliance for flexible supporting constructions.
  • Installation Requirements:
    • Minimum timber thickness of 75mm for vertical and horizontal members.
    • Full-height vertical supports tied securely into the floor and ceiling structure.
    • Wall construction must achieve 60-minute fire resistance, typically via two layers of 12.5mm fire-rated plasterboard.
    • Dependable Performance – Curtain weight approx. 12 kg/m², ensuring consistent controlled descent and fire integrity throughout rated exposure time.

 

Operation & Controls

  • Motorised Operation – Powered by a single-phase tubular motor as standard for smooth and reliable functionality.
  • Fire Alarm Integration – Fully compatible with building management or fire alarm systems for automatic activation during emergencies.
  • Control Options Include:
    • Fire alarm interface card
    • UPS battery backup or gravity fail-safe motor
    • Audio-visual alert panels
    • Emergency override and release switches
    • Delay or two-stage descent programming

 

Installation & Warranty

  • Made-to-Measure Design – Custom-built for openings up to 7m x 7m, depending on fire rating and wall type.
  • Flexible Mounting – Suitable for face-fix or reveal-fix installation on stud and partition walls, supplied with full technical drawings and plate sizing charts for accurate specification.
  • Quality Assured – Manufactured to strict quality control standards and supported by a 12-month warranty (extended options available upon registration).

 

Lead Time & Typical Applications

  • Typical Lead Time: 3-4 weeks (15-20 working days), depending on finish and configuration.
  • Ideal For:
    • School corridors and classroom partitions
    • Office compartments and meeting rooms
    • Retail counters, kiosks, and concession areas
    • Canteens and kitchen serveries
    • Lightweight or modular construction projects

 

Design & Customisation

  • Finish Options: Supplied galvanised as standard for long-lasting corrosion protection.
  • Powder Coating Available: Choose from a wide range of RAL and BS colours to match interior design schemes.
  • Compact Headbox Design: Integrated tubular motor allows for a minimal housing profile, perfect for modern interiors with limited space or aesthetic requirements.
  • Customisable Canopy & End Plates: Manufactured to suit installation type and visual preference.
Structural Requirements

This video shows the requirements for fitting a fire shutter into a flexible structure ie; Timber Stud Wall.

Electrical Requirements

This video explains what is required in regards to the Power Supply and Fire Alarm Interface for Compact Fire Shutters.

Need more information?

Speak to one of our specialist advisors for more information about this product.