Steel Roller Shutters

Servery Fire Shutter – Rigid Structure

From only £1,825.00 Ex VAT (£2,190.00 inc VAT)
(Based on 1000mm x 1000mm)

Get in Touch Today

Enquire Online or give us a Call

Key Product Features

Application

Serveries

Fire Rating

60mins

Electric Operation

Single Phase - Tube or Industrial Motor

Max Width

8000mm (Depending on Height)

Max Height

3020mm (Depending on Width)

Box and Guides - Standard Finish

Galvanised

Curtain - Standard Finish

Galvanised

Lead Times

15-20 working days

Servery Fire Shutters for Rigid Structures

Our Servery Fire Shutters for Rigid Structures are specifically tested and certified for installation onto masonry, concrete, and structural steel supporting constructions. This makes them the ideal choice for kitchens, school canteens, cafés, bars, receptions, and commercial serveries where the surrounding structure is a solid, non-flexible substrate.

Unlike many servery shutters on the market, this system has been independently tested as a servery opening on rigid construction, ensuring full compliance with certification requirements and guaranteed acceptance by Building Control and Fire Officers.

The shutter is available with 60-minute minute fire integrity ratings, allowing you to select the correct level of protection based on your fire strategy and site requirements.

 

Key benefits

  •  Tested and certified as a servery opening, approximately 900mm from FFL
  • Approved for Rigid wall type - Concrete, Masonry and Protected Structural Steel
  • Available with 60-minute (E60) fire integrity rating.
  • Integrates with building fire alarm and detection systems for automatic closure.
     

Where it is used

Typical applications include:

  • School and college serveries
  • Restaurant and café counters
  • Commercial kitchen hatches
  • Reception desks and public-facing serveries
  • Healthcare and hospitality counters
     

Fire ratings and sizes


E60 – 60-minute fire integrity

  • Tube motor (size range limited)
  • Industrial motor up to approx. 8000 mm W × 2400 mm H clear opening
  • Test Report – 552862 with Technical Report FPA107941

 

Tested / classified to:

  • BS EN 1634‑1 – Fire resistance testing of doors and shutters
  • BS EN 15269‑10
  • EN 13501‑2 – Fire classification of construction products
  • CE marked to BS EN 16034

 

Suitable wall types (Rigid Structures)

Designed for Rigid supporting constructions such as:

  • Concrete and Masonry -
    • Min Density 1600kgsm2
    • 102.5mm thick
       
  • Protected Structural Steel

    • Structural Steel Section Factor (A/V): Must be <230 m⁻¹.   
    • Box Section - Min. 60mm x 120mm x 5mm Rectangular hollow section (RHS)
    • MUST be protected on all 4 Sides to the fire rating of the shutter.
      • EN13381-4 - Passive - Fire Boarded
      • EN13381-8 - Reactive - Intumescent Paint

    For detailed requirements see our Fire Shutter Substrate Guide.

Landing surfaces

The shutter must close onto a compliant landing surface to maintain fire integrity. Typical options include:

  • Masonry or concrete worktop
  • Steel cill angle
  • Class A1 non‑combustible substrate (EN 13501)
     

Controls & Safety Features

Every Servery Fire Shutter includes:

  • Fire Control Panel – standard or staged descent
  • Audio-Visual Warning – mandatory for serveries
  • Battery Backup Unit – ensures automatic closure under power loss
  • Integration with fire alarm or independent detectors
  • Emergency escape options where required

    For more details see our Fire Shutter Controls Guide


 

Information

Key Features – Servery Fire Shutter (Rigid Structure)
 

Certified for Rigid Supporting Walls

  • Specifically tested and approved for Rigid wall constructions - Masonry, Concrete and Structural Steel
  • Fully compliant with Building Control requirements for serveries

Independently Tested as a Servery Opening

  • Certified for installation 900mm above finished floor level, ensuring full acceptance by Fire Officers.
  • Provides reliable fire compartmentation for commercial serveries and food counters.

Up to 60 Minutes Fire Integrity

  • Available with E60 (60-minute) fire ratings.
  • Tested to BS EN 1634-1, BS EN 15269-10, and classified to EN 13501-2.
  • CE Marked to BS EN 16034 for assured compliance.

Flexible Motor Options

  • Tube motor available for compact or smaller openings.
  • For 60-minute rating: industrial motor options available for larger openings up to 8000mm × 2400mm.

Designed for Masonry, Concrete and Structural Steel

  • Concrete and Masonry - Min Density 1600kgsm2 - 102.5mm thick
  • Structural Steel Section Factor (A/V): Must be <230 m⁻¹.  MUST be protected on all 4 Sides to the fire rating of the shutter.

Compatible Landing Surface Options

Closes onto a compliant non-combustible surface to maintain fire integrity, such as:

  • Masonry or concrete worktops
  • Steel cill angles
  • Class A1 substrates

Integrated Fire Safety Controls

  • Comes with a Fire Control Panel (standard or staged descent).
  • Audio-Visual Warning system included—mandatory for serveries.
  • Battery Backup Unit ensures closure during power failure.
  • Seamless integration with the building’s fire alarm, smoke detectors, or heat detectors.
Structural Requirements

This video shows the requirements for fitting a fire shutter into a flexible structure ie; Timber Stud Wall.

Electrical Requirements

This video explains what is required in regards to the Power Supply and Fire Alarm Interface for Compact Fire Shutters.